Brands |
N/A Electro-Steam™ |
Electrical Power |
N/A 10 kW |
Boiler Horse Power |
N/A 1 bhp |
Alternating Current (AC) Power Supply Voltage1 | N/A 208 V230 V380 V415 V440 V480 V600 V |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Approximate Heat Up Time |
N/A 25 min |
Steam Capacity2 | N/A 34.5 lb/hr15.7 kg/hr |
Water Consumption |
N/A 4.13 gal/hr15.7 L/hr |
Gross British Thermal Units (BTU) Output |
N/A 33,475 Btu/hr |
Maximum Boiler Pressure |
N/A 200 psi |
Operating Pressure Range |
N/A 5 to 160 psi |
Operating Pressure (Factory Set Point) |
N/A 160 psi |
Boiler Temperature |
N/A 212 to 371 ºF |
Temperature at Tip |
N/A 212 to 250 ºF |
Maximum Boiler Capacity |
N/A 6 gal |
Boiler Fill Capacity |
N/A 4.2 gal |
Reservoir Tank Capacity |
N/A 7 gal |
Boiler Material 3 | N/A Carbon Steel |
Cabinet Material |
N/A 304 Stainless Steel |
Plumbing Material |
N/A Brass (Schedule 80) Carbon Steel (Schedule 80) |
Crated Weight |
N/A 725 lb |
Cleaning Method |
N/A Dry Steam |
Industry Standards |
N/A American Society of Mechanical Engineers (ASME) - CSD-1 Compliant American Society of Mechanical Engineers (ASME) - Miniature Boiler Code American Society of Mechanical Engineers (ASME) Section I - V-Stamp Underwriters Laboratories (UL 353) |
Amperage at 208 VAC (3Ø Phase) |
N/A 38.6 A |
Amperage at 240 VAC (3Ø Phase) |
N/A 38.7 A |
Amperage at 380 VAC (3Ø Phase) |
N/A 21.8 A |
Amperage at 415 VAC (3Ø Phase) |
N/A 21.1 A |
Amperage at 440 VAC (3Ø Phase) |
N/A 18.9 A |
Amperage at 480 VAC (3Ø Phase) |
N/A 18.3 A |
Amperage at 600 VAC (3Ø Phase) |
N/A 15.1 A |