Brands |
N/A Electro-Steam™ |
Variant |
N/A Low Pressure |
Electrical Power |
N/A 30 kW |
Power Supply Voltage1 | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC |
Phase2 | N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Boiler Horse Power |
N/A 3.0 bhp |
Steam Capacity3 | N/A 103.5 lb/hr46.95 kg/hr |
Water Consumption |
N/A 12.4 gal/hr46.95 L/hr |
Gross British Thermal Units (BTU) Output |
N/A 100,426 Btu/hr |
Maximum Boiler Pressure |
N/A 15 psi |
Operating Pressure (Factory Set at 11 Pound per Square Inch (psi)) |
N/A 0 to 11 psi |
Maximum Boiler Capacity |
N/A 6 gal |
Boiler Fill Capacity |
N/A 4.2 gal |
Boiler Material 4 | N/A Carbon Steel |
Cabinet Material |
N/A 304 Stainless Steel |
Plumbing Material |
N/A Brass (Schedule 40) Carbon Steel (Schedule 40) |
Industry Standards |
N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) 834 |
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 83.30 A |
Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 78.60 A |
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 45.60 A |
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 41.70 A |
Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 39.40 A |
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 36.10 A |
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 28.90 A |
Overall Height |
N/A 23 in |
Overall Length |
N/A 27 in |
Width (No Options Included) |
N/A 23 in |
Width (Motorized Automatic Flush and Drain (MAFD) Option Included) |
N/A 26 in |
Width (Single Service Transformer Option Included) |
N/A 28 in |
Width (Motorized Automatic Flush and Drain (MAFD) & Single Service Transformer Options Both Included) |
N/A 31 in |
Water Inlet |
N/A 3/8" NPT (National Pipe Thread) (Female) - Y-Strainer, Brass |
Steam Outlet |
N/A 1/2" NPT (National Pipe Thread) (Female) - Ball Valve, Brass |
Safety Valve |
N/A 3/4" NPT (National Pipe Thread) (Female) - Safety Valve, Brass |
Drain |
N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, Brass |
Additional Drain (Motorized Automatic Flush and Drain (MAFD) Option Included) |
N/A 3/4" NPT (National Pipe Thread) (Female) - Motorized Valve, Brass |
Spare Parts Package Includes |
N/A
|
Motorized Automatic Flush and Drain (MAFD) |
N/A During Start-Up before steam pressure is accumulated, the Motorized Automatic Flush and Drain option cycles fresh water through the boiler for 0-300 seconds (Factory set for 180 seconds or three (3) minutes). As old water is drained out, fresh water will be cycled in. This drain valve will not open if boiler pressure exceeds 5 psi, and the electric heaters are locked out during flush cycle. |
Single Service Transformer |
N/A Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required. |
5-Micron Water Filter |
N/A 2-stage, 5-micron water filter installed into incoming water line to reduce sediment, dirt, rust, chlorine, and even odor from incoming water supply. |
Manual Low Water Reset5 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. |
Portable Mounting Includes |
N/A
|
Water Feed Booster Pump |
N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressureis below this requirement, this option must be added. The Water Feed Booster Pump increases your incomingwater pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-80 psiwater supply with a minimum flow rate of 2 gpm. |