Brands |
N/A Electro-Steam™ |
Variant |
N/A Low Pressure |
Electrical Power |
N/A 50 kW |
Power Supply Voltage1 | N/A 208 VAC230 VAC380 VAC415 VAC440 VAC480 VAC600 VAC |
Phase |
N/A 3 |
Frequency |
N/A 50 Hz60 Hz |
Boiler Horse Power |
N/A 5.00 bhp |
Steam Capacity2 | N/A 172.50 lb/hr78.24 kg/hr |
Water Consumption |
N/A 20.67 gal/hr78.24 L/hr |
Note for Water Consumption |
N/A Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF. |
Gross British Thermal Units (BTU) Output |
N/A 167377 Btu/hr |
Maximum Boiler Pressure |
N/A 15 psi |
Operating Pressure |
N/A 0 to 11 psi |
Maximum Boiler Capacity |
N/A 15 gal |
Boiler Fill Capacity |
N/A 11 gal |
Boiler Material 3 | N/A 316L Stainless Steel |
Cabinet Material |
N/A 304 Stainless Steel |
Plumbing Material |
N/A 316L Stainless Steel (Schedule 40) |
Industry Standards |
N/A American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code American Society of Mechanical Engineers (ASME) - CSD-1 Canadian Underwriters Laboratories (cUL) Underwriters Laboratories (UL) |
Amperage at 208 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 138.80 A |
Amperage at 240 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 131.00 A |
Amperage at 380 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 76.00 A |
Amperage at 415 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 69.60 A |
Amperage at 440 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 65.60 A |
Amperage at 480 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 60.10 A |
Amperage at 600 Volt (V) Alternating Current (AC) Voltage (3Ø Phase) |
N/A 48.10 A |
Water Inlet |
N/A 1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS) |
Steam Outlet |
N/A 3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS |
Safety Valve |
N/A 3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body. |
Drain |
N/A 1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS) |
Spare Parts Package Includes |
N/A
|
Single Service Transformer |
N/A Supplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required. |
Manual Low Water Reset4 | N/A Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production. |
Portable Mounting Includes |
N/A
|
Water Feed Booster Pump |
N/A The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm. |